亚洲色偷偷色噜噜狠狠99_9977精品视频网站免费观看_亚洲久最新获取地址4_国产十八禁止久久影院

Language

搜索

搜索

How to solve the problem of drum synchronization shaft fracture?

Creation time:2024-07-17 Author:管理員 View:105
1. Design reasonsCoupling type is reasonable, torque is satisfied, R Angle is appropriate.2. Manufacturing reasonsWhether the material is correct, there are no defects, whether the processing circle jump is satisfied, and whether the R Angle processing is in place.3. Reasons for arrangementWhether the two drum shafts at both ends of the synchronous coupling meet the requirements of the coupling.Similarly, several members of the group have suggested several solutions:1. Frequency conversion contr

1. Design reasons

Coupling type is reasonable, torque is satisfied, R Angle is appropriate.

2. Manufacturing reasons

Whether the material is correct, there are no defects, whether the processing circle jump is satisfied, and whether the R Angle processing is in place.

3. Reasons for arrangement

Whether the two drum shafts at both ends of the synchronous coupling meet the requirements of the coupling.

Similarly, several members of the group have suggested several solutions:

1. Frequency conversion control is adopted for electrical control. Choose 2 frequency converters, each control a YZP motor, two frequency converters to do the torque equal division can be. The inverter increases the output reactance, and the motor increases the backpack cooling fan (although this can not replace the original motor, it is still recommended to use the YZP series motor).

2. The reducer is equipped with ratchet pawl.

3, motor with the same batch, brake with the same batch.

4. Thicken the diameter and R Angle of the drum shaft to increase the coupling specifications.